Use the tools below to refine your search by only displaying reviews with a certain number of star ratings or to only show reviews from a certain time period. Eg click on '1 star' to just display the reviews we have which received a 1 star rating click or 'Within the last month' to display just reviews posted over the last month.

  • Average Rating Over Time
  • Within the last month ***** (From 0 reviews)
  • Within the last 6 months *** (From 0 reviews)
  • Within the last 12 months * (From 0 reviews)

Latest Reviews

★☆☆☆☆
Qualcast Hedgemaster 420

“I did the dreaded thing about two years ago by cutting...”

Written on: 25/07/2008 by C Carruthers (1 review written)

I did the dreaded thing about two years ago by cutting through the cable. The provided 13-amp 'protection' failed and left a potentially lethal situation. I took up the matter with Qualcast who fobbed me off about their choice of a 13-amp fuse within the plug. Because the device has a 380-watt consumption, my basic knowledge of matters electrical induced me to replace Qualcast's 13-amp fuse with a 3-amp fuse and all went well. A few days ago I was careless enough to sever the cable again… Read Full Review

If you are commenting on behalf of the company that has been reviewed, please consider upgrading to Official Business Response for higher impact replies.

291866_Pleasant's Response to C Carruthers's Review

Written on: 27/03/2009

....having cut through the cable twice in quick succession I would suggest it isn't Qualcast who are- as you state- "stupid buggers"<br/><br/>Maybe a pair of scissors would be more appropriate for you.

Reply to this comment
If you are commenting on behalf of the company that has been reviewed, please consider upgrading to Official Business Response for higher impact replies.

Davebevrach's Response to C Carruthers's Review

Written on: 28/04/2013

Only a RCD cut off device would protect you more than a 3 or 13 amp fuse in such a device. A 3 amp fuse would offer no more protection from shocks than a 13 amp one. Both are likely to blow easily when you cut the cable but offer no shock protection if they don't blow. In addition all devices with electric motors require an initial higher start up current as the motor runs up to fell speed so a 3 amp fuse is likely to fail without any faults in the machine. Perhaps a little more knowledge is needed before you criticise a responsible company. I teach Physics.